- 12.1'' color TFT LCD displaying real-time date and waveform.
- It can synchronously display eight-channel waveform and full monitoring parameters equipped with an optional 48mm thermal recorder.
- Monitors parameters such as ECG, RESP, NIBP, SpO2, and dual-channel TEMP, etc.
ECG:
- Lead mode: 3-lead or 5-lead
- Lead selection: I; II; III; AvR; AvL; AvF; V
- Heart rate range: Adult: 15-300bpm; Pediatric/Neonatal: 15-300bpm
- ECG waveform: 2 channels
- Accuracy: ± 1 bpm or ± 1%
- S-T segment detection Measurement range: -0.2mv~2.0mv
- Alarm: Yes, audible and visual alarm, alarm events review
- High resolution 12.1"color TFT display
- Lightweight, compact and portable
- ECG, APO2, NIBP, RESP, 2-TEMP, PR
- Optional: 2-IBP, ETCO2, And a thermal printer
- Built-in rechargeable lithium battery
- ECG waveforms of 7-leads display on the same screen
- 72-hours graphic and tabular trends of all parameters
- 72 alarm events of all parameters recall
- 32 seconds full-disclosure waveform review
SpO2:
- Measurement range: 0-100%
- Accuracy: 70-100%, ± 2% 0-69%, unspecified Pulse rate
- Range: 20-254bpm
- Accuracy: ± 3bpm
Respiration:
- Method: RA-LL impedance
- Range: Adult: 0-120rpm; Pediatric/neonatal: 0-150rpm
- Apnea alarms: Yes
Temperature:
- Range: 0-50
- Apnea: 0.1
- Channel: Dual-Channel
- Method: Oscillometry
- Modes: Manual/Auto/Comtinuous
- Auto measure time: Adjustable
- Measurement rang: 10-270mmHg
ECG:
- Lead mode: 3-lead or 5-lead
- Lead selection: I; II; III; AvR; AvL; AvF; V
- Heart rate range: Adult: 15-300bpm; Pediatric/Neonatal: 15-300bpm
- ECG waveform: 2 channals
- Accuracy: ± 1 bpm or ± 1%
- S-T segment detection Measurement rang: -0.2mv~2.0mv
- Alarm: Yes, audible and visual alarm, alarm events review
- High resolution 12.1"color TFT display
- Lightweight, compact and portable
- ECG, APO2, NIBP, RESP, 2-TEMP, PR
- Optional: 2-IBP, ETCO2, And thermal printer
- Bulit-in rechargeable lithium battery
- ECG waveforms of 7-leads display on the same screen
- 72-hours graphic and tabular trends of all parameters
- 72 alarm events of all parameters recall
- 32 seconds full-disclosure waveform review
- 500 NIBP measurement date can be storage and recall
- Date and waveforms color be adjustable
- Arrhythmia analysis and S-T segment analysis
- Suitable for adult, pediatric and neonatal patient
SpO2:
- Measurement range: 0-100%
- Accuracy: 70-100%, ± 2% 0-69%, unspecified Pulse rate
- Range: 20-254bpm
- Accuracy: ± 3bpm
Respiration:
- Method: RA-LL impedance
- Range: Adult: 0-120rpm; Pediatric/neonatal: 0-150rpm
- Apnca alarmYes
Temperature:
- Range: 0-50
- Apnca: 0.1
CMS8000 5 Para Patient Monitor
₹33,000.00Price